FirePause
Home About Us Products Blog Cart 0 Contact
Training Certifications Contact
Fire Fighting Equipment

Automatic Diesel Engine Room Fire Suppression System (10L)

SKU: FF-VEHICLE-DIESEL Type: Vehicle Fire Suppression
Estimated Price
₹16500
* Price excl. 18% GST | Transport extra
Automatic fire suppression system for diesel engine rooms, generator sets, and heavy machinery
Description & Overview

Automatic Diesel Engine Room Fire Suppression System

???? AUTOMATIC ACTIVATION ???? HEAVY MACHINERY

???? Product Overview

The Automatic Diesel Engine Room Fire Suppression System (10L) provides 24/7 unattended fire protection for diesel engines, generator sets, heavy machinery, and marine engine rooms. This fixed-installation system detects fire automatically and discharges ABC dry chemical powder directly onto the hazard area.

Ideal for: Generators, excavators, bulldozers, mining equipment, marine vessels, agricultural machinery, and stationary diesel engines.

✨ Key Features

  • Capacity: 10 Liters ABC dry chemical powder
  • Activation: Automatic (135°C thermal detector) + Manual pull cable option
  • Coverage: Up to 8 cubic meters (customizable)
  • Discharge Time: 15-20 seconds total
  • Nozzles: 3-6 strategically placed nozzles (included)
  • Detection: Linear heat detection tubing or thermal detectors
  • Control Unit: Pneumatic/mechanical - no electricity required
  • Temperature Range: -40°C to +85°C
  • Construction: Heavy-duty steel cylinder with corrosion-resistant coating
  • Rechargeable: Yes - refillable after discharge

⚙️ Technical Specifications

ParameterSpecification
System TypeFixed automatic/manual override
Cylinder Pressure1800 PSI (pre-charged nitrogen)
Detection MethodLinear heat detection tubing (135°C)
Activation Temperature135°C ± 5°C (adjustable)
Discharge AgentABC multipurpose dry chemical
Agent Weight10 kg
Control HeadPneumatic valve with pressure gauge
CertificationsUL, FM, CE, SOLAS (marine version available)
StandardsNFPA 17, ISO 7076, EN 12094

???? System Components (Complete Kit)

  • Primary Cylinder: 10L pressurized agent cylinder
  • Control Head: Pneumatic actuation with pressure gauge
  • Detection Tubing: 15 meters linear heat detection (135°C rated)
  • Discharge Nozzles: 4 x brass directional nozzles
  • Manual Pull Station: Remote cable-actuated pull handle
  • Stainless Steel Tubing: 10 meters discharge piping
  • Mounting Brackets: Heavy-duty hardware set
  • Warning Signage: "AUTOMATIC FIRE SUPPRESSION" decals
  • Installation Kit: Fittings, unions, and teflon tape
  • Manual: Complete installation and maintenance guide

⚡ How It Works - Step by Step

  1. Detect: Linear heat detection tubing senses temperature rise beyond 135°C
  2. Activate: Tubing bursts at the hot spot, releasing pressure from pilot line
  3. Deploy: Pressure drop triggers control head, opening agent cylinder valve
  4. Discharge: ABC powder travels through pre-installed piping
  5. Deliver: Strategic nozzles direct agent to engine, alternator, and fuel pump areas
  6. Suppress: Flame knockdown achieved within seconds
  7. Manual Option: Pull cable provides operator-initiated activation before automatic triggers

????️ Specific Applications

  • Diesel Generators: Standby and prime power generators (100kW - 2MW)
  • Mining Equipment: Haul trucks, loaders, excavators, drills
  • Construction Machinery: Bulldozers, graders, backhoes, compactors
  • Marine Vessels: Boat engine rooms, yacht engine compartments
  • Agricultural Equipment: Tractors, harvesters, cotton pickers
  • Rail Locomotives: Diesel-electric locomotive engine bays
  • Waste Compactors: Stationary and mobile compactor engines
  • Oil & Gas: Pump jack engines, compressor stations

✅ Key Advantages

  • Unattended Operation: Works 24/7 without human intervention
  • No Power Required: Pneumatic system operates independently of vehicle electrical system
  • Fast Response: Detection to discharge within 3-5 seconds
  • Prevents Total Loss: Protects expensive equipment (often $100k-$2M replacement cost)
  • Insurance Reduction: May qualify for equipment insurance premium discounts
  • Reusable: System can be recharged and reset after discharge
  • Retrofit Friendly: Can be installed on existing equipment
  • Manual Override: Operator can activate system before automatic triggers

???? Installation Guidelines

  • Professional installation recommended by certified technician
  • Place nozzles to cover: engine top, alternator, turbocharger, fuel injection pump, exhaust manifold
  • Run detection tubing through highest fire risk areas
  • Mount pull cable within reach of operator seat
  • Install warning labels prominently in cabin and engine bay
  • Pre-commissioning test recommended

????️ Maintenance Schedule

  • Daily (Operator): Check pressure gauge (green zone), verify pull cable free movement
  • Monthly: Inspect nozzles for obstruction, check detection tubing for damage
  • Annually: Professional service - weigh cylinder, inspect all components
  • Every 6 Years: Cylinder hydrostatic testing and agent replacement

Common Safety Queries

How often should extinguishers be serviced?

For optimal safety, commercial extinguishers should be inspected monthly and professionally serviced annually as per strict fire safety standards.

What is the lifespan of a fire extinguisher?

Most dry chemical extinguishers last between 10-12 years if maintained correctly, but the propellant and cylinder integrity must be checked regularly.

Ready to Protect Your Property?

Get a free site assessment and expert product recommendation from our certified fire safety engineers today.

📞 Call Now
0 Items Price: On Request