FirePause
Home About Us Products Blog Cart 0 Contact
Training Certifications Contact
🧯

Fire Extinguishers

Certified Fire Extinguisher Installation, Refilling & AMC

🛡️ Govt. Licensed Agency (Directorate of Maharashtra Fire Services)
📜 ISO 9001:2015 Quality Certified
⚖️ NBC Part 4 / IS Compliance
🧯 ISI & EN-54 Certified Products

We provide comprehensive supply, installation, hydrostatic pressure testing, and periodic refilling for all types of fire extinguishers. Our services strictly follow the IS 2190 guidelines to ensure complete hazard readiness.

Certified Fire Extinguisher Refilling & AMC Services

In accordance with the stringent guidelines of the IS 2190 compliance codes, maintaining functional fire extinguishers at standard heights is a critical statutory requirement for corporate towers, factories, and housing societies in Maharashtra. FirePause provides robust fire extinguisher refilling near me solutions alongside heavy-duty cylinders sourcing and annual maintenance contracts (AMC).

🧯 Types & Classifications of Fire Extinguishers We Install

We supply, commission, and refill a complete array of ISI-marked portable and trolley-mounted fire cylinders:

  • ABC Dry Chemical Powder (DCP) Extinguishers: Formulated with mono-ammonium phosphate (MAP 90%) for organic solids, flammable liquids, and electrical fire hazards.
  • Carbon Dioxide (CO2) Extinguishers: Crucial for server rooms, UPS setups, and lab panels as they leave zero residue and prevent electronic damage.
  • Clean Agent Extinguishers: Utilizes premium HFC-236fa gas which is eco-friendly, non-conductive, and highly effective for sensitive server clusters.
  • Mechanical Foam (AFFF) & Water Extinguishers: Engineered for Class A (wood, paper) and Class B (petrol, paint) risk containment.

📜 B2B Annual Maintenance Contracts (AMC) & Audits

Under the Maharashtra Fire Act, all commercial premises must maintain active safety equipment logs. Our quarterly B2B AMC audits cover:

  • Visual check of pressure gauges to ensure they sit in the green zone.
  • Physical weight assessment to detect chemical leakage or gas discharge.
  • Clearing discharge nozzles, hose pipes, and horns from blockages or nests.
  • Lubricating the operating trigger mechanism and checking safety pins and plastic tags.
  • Mounting bracket inspections to ensure cylinders are hung at standard heights (max 1.5 meters from floor).

💧 Hydrostatic Pressure Testing (HRT) Requirements

Cylinder shells are subjected to extreme pressure. To prevent accidents, IS 2190 mandates that water-type, powder, and foam extinguishers undergo hydrostatic testing at 35 kg/cm² pressure every 3 to 5 years, while CO2 cylinders are tested at 250 kg/cm² in certified labs.

🏷️ Mandatory Safety Markings, Labels, & Mounting Standards (IS 15683)

Per Indian Standard IS 15683:2018, all portable fire cylinders must carry specific marking characteristics to comply with fire audits. This includes permanent stamping of the unique ISI license number, manufacturer details, test pressures, and manufacturing year. Cylinders must be coated in Signal Red (RAL 3000) and display a color-coded band corresponding to the agent class.

Cylinder Mounting Height Rules: Fire extinguishers with a gross weight of less than 4kg must be mounted so the handle sits no higher than 1.5 meters from the finished floor level. For heavier cylinders exceeding 4kg, the mounting height must be restricted to 1.0 meter max, ensuring swift access during panic situations.

📋 Fire Extinguisher Selection & Class Suitability Matrix

Selecting the correct extinguishing medium is vital. Using the wrong agent can exacerbate the hazard, especially on electrical or grease fires:

Extinguisher Type Active Agent Suitable Fire Classes Typical B2B Application
ABC Dry Powder Mono-Ammonium Phosphate (MAP 90%) Class A, B, C General Offices, Warehouses, Corridors
Carbon Dioxide (CO2) Liquid CO2 under pressure Class B, C (Electrical) Server Rooms, UPS Rooms, Electrical Panels
Clean Agent HFC-236fa Gas (Non-conductive) Class A, B, C Data Centers, Labs, High-Value Archives
Water / Foam Water + AFFF Foam concentrate Class A, B Textile Mills, Paper Storage, Fuel Depots

Why Choose FirePause in Maharashtra

📍 Proximity & Fast Response

Local dispatch hubs across Mumbai, Pune, Thane, Navi Mumbai, and Nashik enable our certified safety engineers to arrive at your premises in under 45-60 minutes for site audits or emergency refills.

⚖️ End-to-End Form B Support

We are a government-licensed safety contractor. We manage the automated scheduling and filing of your statutory Form B compliance certificates twice a year in January and July, avoiding compliance notice seal-outs.

🧯 Premium OEM Accreditations

Every piece of fire-fighting equipment supplied by FirePause is ISI-marked and manufactured under strict ISO 9001:2015 guidelines, guaranteeing absolute reliability in critical situations.

🚨 24/7 Dedicated B2B AMC Desk

Corporate AMC customers enjoy round-the-clock technician dispatch, quarterly scheduled line audits, free emergency standby cylinders, and compliance licensing consultations.

Interactive B2B Cost Estimator
Estimate your fire protection setup and compliance budget parameters in seconds.
Estimated Budget Range
₹18,000 - ₹35,000
Expected Compliance Timeline
7 - 10 Days

Technical & Compliance Specifications

Compliance Standard IS 2190:2010 (Selection, Installation & Maintenance) / IS 15683:2018 (Manufacture)
Classes Covered Class A (Organic solids), Class B (Liquids), Class C (Gases), Class D (Metals), Class K (Fats/Oils)
Cylinder Capacities CO2 (2kg, 4.5kg, 6.5kg, 9kg, 22.5kg) / Powder & Clean Agent (1kg, 2kg, 4kg, 6kg, 9kg)
Warranty Provided 1 to 5 Years OEM Warranty on New ISI-Marked Equipment
Hydrotesting Cycle Mandatory every 3 years for Clean Agent/CO2; 5 years for Water/Powder (IS 2190 norms)
AMC Frequency Quarterly / Semi-Annual audits with pressure checks, weight logs, and nozzle cleaning

Installation & Service Process

01
Hazard Assessment & Placement

Our licensed engineers inspect your layout to identify class risks (electrical, chemical, organic) and specify correct heights, placement intervals, and locations.

02
Procurement & Mounting

Installation of certified ISI-marked cylinders with heavy-duty mounting brackets, proper safety pins, and visible warning labels.

03
Quarterly AMC Inspections

Periodic checking of weight, pressure gauges, nozzles, and seals. We log every inspection on physical compliance tags and our digital database.

04
Refilling & Gas Pressurization

Discharging, interior cleaning, hydro-testing (HRT) at required pressure, refilling with premium chemicals, and pressurizing with dry nitrogen gas.

05
Compliance Form B Signoff

Submission of certificate of compliance and issuing dynamic documentation required for Maharashtra Fire Services Form B filing.

Interactive Simulator

🧯 Fire Extinguisher Anatomy & Discharge

Learn how to inspect and discharge a portable ABC Dry Powder cylinder. Click the safety pin to pull it, then hold down the lever to spray.

FIREPAUSE ABC POWDER IS 15683:2018
🔥

Simulator Controls

Extinguisher Locked
The yellow safety pin is in place, preventing accidental discharge. The pressure needle shows that the cylinder is fully pressurized (Green zone). Click the pin to pull it out.

🛠️ System Component Breakdown

Learn about the physical components and engineering modules that power this safety service.

Monitoring

Pressure Gauge

Indicates if the cylinder has sufficient nitrogen gas pressure to discharge the chemical agent during emergencies.

Safety

Safety Pin & Seal

A metal pin held by a plastic tamper seal that locks the operating lever in place, preventing accidental activation.

Discharge

Hose & Horn

A rubber tube and wide horn designed to accurately direct and expand the extinguishing chemical towards the base of a fire.

POWDER
Storage

Cylinder Shell

A heavy-duty steel container pressurized with nitrogen gas, coated in Signal Red paint for high visibility.

Industries We Protect

🏭
Factories & Warehouses
High-risk suppression piping, deluge loops, and compliance audits for MIDC areas.
🏢
Commercial IT Parks
Smart addressable alarm grids, sprinkler loops, and exit light integrations.
🏬
Retail & Showrooms
Aesthetic sprinkler layout design and certified Class A/B/C extinguishers.
🏥
Hospitals & Clinics
Evacuation route signage maps, sound alarms, and compliance fire audits.
🏨
Hotels & Restaurants
Kitchen gas leakage systems, heat sensor relays, and staff safety training.
🏘️
Housing Societies
Biannual Form B inspections, hydrant pressure testing, and refilling AMCs.

Service Frequently Asked Questions

How often do fire extinguishers need refilling in Maharashtra? +
According to IS 2190 guidelines, fire extinguishers must be refilled immediately after any discharge (even partial) or when pressure levels fall. If unused, they must be serviced annually and undergo mandatory hydro-testing every 3 to 5 years depending on the type.
What chemical agents are used for electrical fires? +
Carbon Dioxide (CO2) or Clean Agent (HFC-236fa or HFC-227ea) extinguishers are the standard for server rooms, electrical panels, and laboratories because they do not leave any residue and are non-conductive, protecting sensitive hardware.
Can we buy fire extinguishers online and install them ourselves? +
While you can purchase them online, compliance with the Maharashtra Fire Prevention Act requires installation at specific heights and locations by a licensed agency like FirePause to ensure they pass government fire audits.
What is hydrostatic pressure testing (HRT) for cylinders? +
HRT is a safety test where the extinguisher cylinder is filled with water and pressurized to its test limit (typically 30-35 kg/cm²). This checks for structural weakness or microscopic leaks, preventing accidental explosions under high pressure.
Request Quote: Fire Extinguishers
Submit your details below. Our B2B compliance engineers will get in touch with you within 30 minutes.
Quote Request Submitted successfully! A B2B representative will call you shortly.
0 Items Price: On Request
Go to Cart