Very Early Smoke Detection Apparatus (VESDA) aspirating system for mission-critical facilities
Description & Overview

High Sensitivity Aspirating Smoke Detector

???? VERY EARLY WARNING ⚡ PARTS PER BILLION SENSITIVITY

???? Product Overview

The High Sensitivity Aspirating Smoke Detector (4 Pipe) actively draws air samples from up to 4 separate pipe networks through a network of sampling holes. Using advanced laser-based particle detection, it can detect smoke at concentrations 1000 times lower than traditional spot detectors - providing minutes to hours of early warning before a fire develops.

Commonly called "VESDA" after the industry leader, this aspirating system is the gold standard for: Data centers, clean rooms, telecom exchanges, power plants, archives, and museums.

✨ Key Features

  • Detection Principle: Laser-based nephelometer (light scattering)
  • Sensitivity Range: 0.001% to 20% obscuration per meter (parts per billion capability)
  • Pipe Networks: 4 independent sampling pipes
  • Maximum Pipe Length: 200 meters per pipe (800 meters total)
  • Sampling Holes: Up to 80 holes per pipe (320 total)
  • Coverage Area: Up to 2,000 m² per detector
  • Fan Flow Monitoring: Individual flow monitoring per pipe
  • Alarm Levels: Alert, Action, Fire 1, Fire 2 (4 programmable thresholds)
  • Air Filter: Field-replaceable filter for dusty environments
  • Display: Graphical LCD with event history and sensitivity bargraph
  • Protocols: 4-20mA, relay outputs, Modbus, BACnet, Ethernet/IP
  • Event Log: 20,000 event memory

⚙️ Technical Specifications

ParameterSpecification
Power Supply18-30 VDC (24 VDC nominal)
Current Draw400 mA typical (600 mA with heater)
Particle Detection Size0.005 - 20 microns
Air Sampling Flow Rate20-100 liters per minute (adjustable)
Operating Temperature0°C to 39°C (heated version to -40°C)
Humidity Range10% to 95% RH non-condensing
Dimensions350 x 250 x 120 mm
IP RatingIP50 (standard), IP65 optional
CertificationsUL 268, EN 54-20, FM, VdS, CE

???? Sensitivity Comparison

  • Traditional Smoke Detector: 2-5% obscuration per meter
  • High Sensitivity ASD: 0.001% obscuration per meter
  • Difference: 2,000 - 5,000 times more sensitive!

This means the aspirating detector can detect smoke when a fire is still smaller than a match head, while traditional detectors would not alarm until flames are visible.

????️ Critical Applications

  • Data Centers & Server Rooms - Prevent fire before equipment damage occurs
  • Clean Rooms - Semiconductor and pharmaceutical manufacturing
  • Telecommunications Facilities - Central offices, telephone exchanges
  • Power Generation - Turbine enclosures, cable tunnels
  • Archives & Museums - Protect irreplaceable documents and art
  • Prisons & Detention Centers - Difficult-to-reach ceiling voids
  • Cold Storage & Freezers - Detectors withstand extreme temperatures
  • High Airflow Areas - Atriums, warehouses, hangars

✅ Why Choose Aspirating Detection?

  • Very Early Warning: Alarms before smoke becomes visible
  • No Detectors in the Space: All electronics in accessible location
  • Ideal for High Airflow: Active sampling overcomes dilution
  • Aesthetic Benefits: Only small sampling holes visible
  • Easy Maintenance: No ladders needed for inaccessible spaces
  • Space Qualified? Can sample from multiple rooms with one detector
  • False Alarm Immune: Multi-stage filtering reduces nuisance alarms

????️ Pipe Network Design Guidelines

  • Maximum pipe length: 200 meters per pipe
  • Maximum sampling holes per pipe: 80
  • Maximum pipe length from detector to farthest hole: 100 meters (balanced design)
  • Minimum pipe diameter: 25mm (1 inch)
  • Pipe material: ABS, PVC, or EMT conduit
  • Sampling hole size: Typically 2-4mm diameter
  • Hole spacing: 4-8 meters typical
  • Capillary tubes: For sampling from above dropped ceilings

Common Safety Queries

How often should extinguishers be serviced?

For optimal safety, commercial extinguishers should be inspected monthly and professionally serviced annually as per strict fire safety standards.

What is the lifespan of a fire extinguisher?

Most dry chemical extinguishers last between 10-12 years if maintained correctly, but the propellant and cylinder integrity must be checked regularly.

Ready to Protect Your Property?

Get a free site assessment and expert product recommendation from our certified fire safety engineers today.

📞 Call Now
0 Items Price: On Request
Go to Cart