FM-200 Gas Suppression System
✨ CLEAN AGENT - NO RESIDUE ???? DATA CENTER APPROVED
???? Product Overview
The FM-200 Gas Suppression System (25kg Cylinder) is an advanced total flooding fire suppression system that uses HFC-227ea (FM-200) clean agent to extinguish fires without damaging sensitive electronic equipment. FM-200 leaves no residue, is electrically non-conductive, and is safe for occupied spaces.
Typical Applications: Data centers, server rooms, telecommunications facilities, control rooms, medical imaging suites, libraries, museums, and clean rooms.
✨ Key Features
- Agent: HFC-227ea (FM-200) - 25kg cylinder
- Fire Classes: A (surface), B, C (electrical)
- Suppression Mechanism: Heat absorption (physical)
- Discharge Time: 10 seconds or less (NFPA requirement)
- Safe for Occupied Spaces: NOAEL = 9% concentration, 6.25% design concentration
- Zero Ozone Depletion Potential: ODP = 0
- Atmospheric Lifetime: 36 years
- Storage Pressure: 25 bar (360 PSI) at 21°C
- Components: Complete kit including cylinder, valve, nozzles, piping, control panel
⚙️ Technical Specifications
ParameterSpecification Cylinder Capacity25 kg FM-200 (HFC-227ea) Cylinder MaterialHigh-strength steel (DOT/TC certified) Design Concentration6.25% - 7.0% (Class A & B fires) Flooding Factor0.72 kg/m³ (Class A), 0.86 kg/m³ (Class B) Maximum Protected VolumeApprox 35 m³ at 7% concentration Operating Temperature0°C to 54°C Discharge DetectionPressure switch for alarm signaling CertificationsUL Listed, FM Approved, CE, LPCB, VdS StandardsNFPA 2001, ISO 14520, EN 15004
???? Complete System Includes
- Agent Cylinder: 25kg FM-200 with siphon tube and valve
- Control Head: Pneumatic or electric actuator
- Control Panel: Intelligent fire alarm and release panel
- Detection: Smoke detectors + optional flame/heat detectors
- Nozzles: Engineered distribution nozzles (quantity based on room geometry)
- Discharge Piping: Schedule 40 steel piping and fittings
- Manual Release: Abort station and manual pull station
- Warning Devices: Horn/strobes for pre-discharge warning
- Pressure Switch: For discharge confirmation
- Engineering Design: Custom nozzle calculation per room
⚡ How FM-200 Suppresses Fire
FM-200 extinguishes fire primarily through heat absorption (physical mechanism), unlike halon which used chemical interruption. When discharged:
- Agent vaporizes immediately upon discharge
- Penetrates throughout the protected enclosure
- Absorbs heat energy from the fire
- Heat absorption interrupts combustion chain reaction
- Reduces temperature below combustion threshold
- Fire is extinguished within 10 seconds
- No residue remains - no cleanup required
- Safe for sensitive electronics, tapes, disks, and documents
???? Ideal Applications
- Data Centers & Server Rooms - Mission-critical IT infrastructure
- Telecommunications Facilities - Switch rooms, central offices, cell towers
- Control Rooms - Power plants, manufacturing control centers
- Medical Facilities - MRI rooms, operating theaters, labs
- Archives & Libraries - Rare books, historical documents, art storage
- Clean Rooms - Pharmaceutical and semiconductor manufacturing
- Museums & Galleries - Priceless artwork and artifacts
- Battery Energy Storage Systems - Lithium battery fire protection
✅ Why Choose FM-200?
- Space Efficient: Stored as liquid, requires less cylinder space than inert gas systems
- Fast Discharge: Typically 10 seconds or less (NFPA requirement)
- No Cleanup: Vaporizes completely - no residue on electronics
- Safe for Occupied Areas: Approved for normally occupied spaces
- Electrically Non-Conductive: Safe for live electrical equipment
- No Cold Shock: Unlike CO₂, doesn't create thermal shock
- Proven Technology: Installed in over 100,000 locations worldwide
- Insurance Friendly: Widely accepted by insurers
???? Design Requirements
- Enclosure must be substantially sealed (leakage area calculation required)
- Ceiling clearance: No suspended ceilings without sealed spaces above
- Hold time minimum: 10 minutes (requires room integrity test)
- Ventilation shutdown required (dampers close automatically)
- Pre-discharge alarm: 20-30 seconds for occupant evacuation
- Abort switch required for occupied areas
????️ Human Safety
- NOAEL: 9% (No Observed Adverse Effect Level)
- LOAEL: 10.5% (Lowest Observed Adverse Effect Level)
- Typical Design Concentration: 6.25% - 7.0% (well below NOAEL)
- Pre-discharge alarm allows occupant evacuation
- No oxygen displacement at design concentrations
- Safe for use in occupied spaces